HOMEAbout UsShell & Tube Plate ExchangersSpiral ExchangersAir-CooledHeat RecoveryBlower &Vent ExchangersPlatefin CoilsElectric Heaters Exhaust & Blower Silencers

Water Coils - Inquiry Form

Company

 

Contact Name

 

Phone

 

Email

 

JobName

 

Model Number

 

Quantity

 

CALCULATOR Conversion Factors - Click to quickly convert Metric/US and more.

DIMENSIONAL DATA

FIN HEIGHT
("A" DIM.)

 

FINNED LENGTH
("B" DIM.)

 

ROWS
DEEP

 

MODEL TYPE

 

FIN SPACING
(FPI, see table)

 

No. of CIRCUTS
(see Note 1)

 

OVERALL HEIGHT
("H"  DIM.)

 

OVERALL LENGTH
("L" DIM.)

 

OVERALL DEPTH
("D" DIM.)

 

FLANGE WIDTHS (see Note 3)

F1

 

F3

 

F2

 

F4

 

 

CONNECTION SIZE (see Note 3)

C1

 

C3

 

C2

 

C4

 

 

CONNECTION SIZE   

CONNECTION TYPE

 Sweat MPT FPT

LEFT HAND COIL SHOWN (RIGHT HAND IS OPPOSITE)

STYLE:       Encases (as shown)       Non-Encased (end plates only)

COIL HAND

Horizontal Airflow:       Left       Right

Vertical Airflow:       Up       Down

COMMENTS:
 

PERFORMANCE DATA

BTUH:

Total

 Sensible

SCFM

 

Face Vel.

 FPM

EDB/EWB

 °F

LDB/LWB

 °F

GPM

 

Fluid (if not water)

 

Entering Fluid Temp.

 °F

Leaving Fluid Temp.

 °F

Fluid Pressure Drop

 Ft. H2O

Air Pressure Drop

 In. H2O

NOTES:

1. To insure proper replacement coil operation, specifyeither number of circuits or complete performance data.

2. Note standard flange widths in table. The F2 dimension shown is  recommended for tube bend protection on most coils

3. Indicate direction of inlet and outlet connection if different from above. If multi-section coil, show circuiting and connection details (use separate sheet if necessary).To insure lowest coil cost, specify required connection location dimensions only if critical to the installation.

AFTER SUBMTTING: Use  browser's BACK button  or  other link  to continue

Model Type

Tube O.D.

Tube C/C
Face x Row

Pattern

Standard Fin Height Increments

Standard Fin Spacing Min-Max

Standard Flange Widths
F1,F3,F4       F2

Standard

L1

38-1
38-2
38-3

3/8
3/8
3/8

1 X 1
1 X 1
1 ¼ X 1

Staggered
Inline
Staggered

2
2
2 ½

10-16
12 only
12-16

1
1
1 ¼

1
1
1 ¼

2 3/8
2 3/8
2 7/8

12-1
12-2
12-3

1 / 2
1 / 2
1 / 2

1 ¼ X 1
1 ½ X 1 ½
1 ½ X 1 ½

Staggered
Staggered
Inline

2 ½
3
3

8-14
10-16
10 only

1 ¼
1 ½
1 ½

1 ¼
1 ½
1 ½

2 7/8
3 3/8
3 3/8

58-1
58-2
58-3

5/8
5/8
5/8

1 ½ X 1 ½
1 ½ X 1 ½
1 ½ X 1.299

Staggered
Inline
Staggered

3
3
3

7-10
8-10
4-15

1 ½
1 ½
1 ½

1 ¾
1 ½
1 ¾

3 5/8
3 3/8
3 5/8

  sales@thermaltransfersystems.com
800-527-0131 • 972-242-9600 • Fax 972-242-7568
THERMAL TRANSFER SYSTEMS, INC. • PO Box 795096 • Dallas, TX 75379-5096
mastercard & visa accepted
Copyright © 1999-2000 Thermal Transfer Systems, Inc. All rights Reserved. All brand, product and company names are tradmarks of their respective holder(s). All information is correct at time of publication, but subject to change without notice. Questions or comments about this site? Contact: Webmaster

HOMEAbout UsShell & TubePlate Exchangers Spiral Exchangers Air-CooledHeat RecoveryBlower &Vent ExchangersPlatefin CoilsElectric Heaters Exhaust & Blower Silencers